OUTPut:TTLTrg:MODE
This command sets the operation of the Trigger Out1 signal to either Function Strobe or Trigger
mode. Factory default is Trigger state which means the OUTP:TTLT:STAT command is required
to generate outputs. This mode is compatible with the Agilent HP6834B models. In Function
Strobe mode, an output pulse is generated automatically any time an output parameter such as
voltage, frequency or phase is programmed. The AC source Trigger Out1 signal is available at a
SMA connector on the rear of the Lx\Ls Series units.
Command Syntax OUTPut:TTLTrg:MODE TRIG | FSTR
Parameters TRIG | FSTR
*RST Value TRIG
Examples OUTP:TTLT:MODE FSTR
Query Syntax OUTPut:TTLTrg:MODE?
Returned Parameters <CRD>
Related Commands OUTP:TTLT:STAT