Programming Manual Lx \ Ls Series II
61
Query Syntax MEASure[:SCALar]:VOLTage:HARMonic:THD?
FETCh[:SCALar]:VOLTage:HARMonic:THD?
Parameters None
Examples MEAS:VOLT:HARM:THD? FETC:VOLT:HARM:THD?
Returned Parameters <NR3>
Related Commands INST:NSEL
MEASure:THDistortion:MODE
This command sets the calculation method for THD measurements. The distortion calculation is
based on the H2 through H50 with the RMS voltage or current in the denominator. Note that some
definitions of THD use the fundamental component (H1) of the voltage or as the denominator.
Lx/Ls units with firmware revision 0.88 or higher can be programmed to use the fundamental
component as the denominator instead of the RMS value. This mode can only be programmed
over the bus by sending the “MEAS:THD:MODE FUND” command. At power up or after a reset
command, the mode will revert back to the RMS mode. This mode setting is not saved in any of
the set up registers.
Syntax MEASure:THDistortion:MODE
Parameters RMSQuare | FUNDamental
Examples MEAS:THD:MODE FUND
Query Syntax MEAS:THD:MODE?
Returned Parameters <CRD>
Related Commands MEAS:VOLT:HARM:THD? MEAS:CURR:HARM:THD?
Commenti su questo manuale