Programming Manual - Rev S Lx \ Ls Series II
226
Appendix C: Error Messages
This appendix gives the error numbers and descriptions that are returned by the AC power
source. Error numbers are returned in two ways:
Error numbers are displayed on the front panel
Error numbers and messages are read back with the “SYSTem:ERRor?” query.
SYSTem:ERRor? returns the error number into a variable and returns two parameters: an
NR1 and a string.
When errors occur, the Standard Event Status register records them as shown in the following
table.
-300 thru -399
or
1 thru 799
Device-dependent
Note that errors over 800 do not set the ESR.
Standard Event Status register error bits
The following table lists the errors that are associated with SCPI syntax errors and interface
problems. It also lists the device dependent errors. Information inside the brackets is not part of
the standard error message, but is included for clarification.
Some error messages are maintained for back ward compatibility with Agilent/HP 6834B models.
Unable to complete
requested operation
Unit may be in a mode inconsistent
with request.
Command syntax
incorrect.
Misspelled or unsupported command
SCPI separator not
recognized
See SCPI section of programming
manual.
Check command for supported data
types
One or more
additional parameters
were received.
Check programming manual for
correct number of parameters
Too few parameters
received for
requested operation
Check programming manual for
correct number of parameters
Invalid command
separator used.
Use semi-colon to separate
command headers
"Program mnemonic too
long"
Check programming manual for
correct command syntax
Check programming manual for
Commenti su questo manuale