Programming Manual Lx \ Ls Series II
114
Command Syntax ABORt
Parameters None
Examples ABOR
Related Commands INIT *RST *TRG TRIG
INITiate:SEQuence
INITiate:NAME
The INITiate commands control the initiation of both the transient generator and the measurement
trigger systems. They cause the trigger system to make a transition from the Idle state to the
Waiting-for-Trigger state. If the trigger system is not in the Idle state, the initiate commands are
ignored.
INITiate:SEQuence and INITiate:NAME initiate the trigger systems to reference trigger
sequences. INITiate:SEQuence references a trigger sequence by its number, while
INITiate:NAME references a sequence by its name. The correspondence between sequence
names and numbers is:
Step, pulse, or list transient trigger sequence
Measurement acquire trigger sequence
Command Syntax INITiate[:IMMediate]:SEQuence[ 1 | 3 ]
INITiate[:IMMediate]:NAME<name>
Parameters For INIT:NAME TRANsient | ACQuire
Examples INIT:SEQ1 INIT:NAME ACQ
Related Commands ABOR INIT:CONT TRIG *TRG
INITiate:CONTinuous:SEQuence
INITiate:CONTinuous:NAME
These commands control the transient generator trigger system.
1 or ON continuously initiates the transient trigger system.
0 or OFF turns off continuous triggering. In this state, the trigger system must be initiated for
each triggered event using INITiate:SEQuence.
INITiate:CONTinuous:SEQuence references the transient trigger sequence by its number, while
INITiate:CONTinuous:NAME references it by its name.
Command Syntax INITiate:CONTinuous:SEQuence[1]<bool>
INITiate:CONTinuous:NAME TRANsient,<bool>
Parameters 0|1|OFF|ON
*RST Value OFF
Examples INIT:CONT:SEQ ON INIT:CONT:NAME TRAN, 1
Related Commands ABOR INIT:CONT TRIG *TRG