Programming Manual Lx \ Ls Series II
109
Command Syntax SYSTem:CONFigure:NOUTputs <n>
Parameters 1 or 3
Examples SYSTem:CONFigure:NOUT 3
Query Syntax SYSTem:CONFigure:NOUT?
Returned Parameters <NR1>
Related Commands CAL:CURR
SYSTem:ETIMe?
This command will return the total number of accumulated hours, minutes and seconds.
Command Syntax SYSTem:ETIMe?
Parameters none
Example SYST:ETIM?
Returned Parameters <NR1>,<NR1>,<NR1>
SYSTem:ERRor?
This query returns the next error number followed by its corresponding error message string from
the remote programming error queue. The queue is a FIFO (first-in, first-out) buffer that stores
errors as they occur. As it is read, each error is removed from the queue. When all errors have
been read, the query returns 0, No Error. If more errors are accumulated than the queue can hold,
the last error in the queue is -350, Too Many Errors.
Query Syntax SYSTem:ERRor?
Parameters None
Returned Parameters <NR1>,<SRD>
Example SYST:ERR?
SYSTem:LANGuage
Sets the command language of the AC Power Source to either SCPI or an available alternate
programming language such as APE (Abbreviated Plain English). The language selection is
stored in non-volatile memory and is retained after power-off. Both the command and query form
can be given regardless of the current language. Note APE is available on Ls models only.
Command Syntax SYSTem:LANGuage:<language>
Parameters SCPI | APEN
Example SYST:LANG:SCPI
Query Syntax SYSTem LANGuage?
Returned Parameters <CRD>
SYSTem:LOCal
This command can only be used with the RS-232 interface. It sets the interface in Local state,
which enables the front panel controls. For GPIB, use the Local bus message, which controls the
ATN control line.
Command Syntax SYSTem:LOCal
Parameters None
Example SYST:LOC
Related Commands SYST:REM SYST:RWL
SYSTem:REMote
This command can only be used with the RS-232 interface. It sets the interface in the Remote
state, which disables all front panel controls except the Local key. Pressing the Local key while in
the Remote state returns the front panel to the Local state. For GPIB, use the Local bus message,
which controls the ATN control line.