Programming Manual - Rev S Lx \ Ls Series II
228
No storage space left
to save settings or
data.
Delete other settings or data to make
room.
Too many waveform
directory entries
Delete one or more waveforms from
waveform memory to make room.
Waveform requested
not in directory
Check waveform directory for
waveform names present.
Too many or non ASCII characters
used in waveform file definition.
Use ASCII characters only
Check hardware for proper operation.
Waveform memory
checksum error.
May be the result of incomplete user-
defined waveform download. Check
interface and try downloading
waveform again. Successful
download may clear this error
condition.
Alternatively, use TRAC:DEL:ALL
command to clear waveform memory.
"Save/recall memory
lost"
User setup register
contents lost
Store setup in same register again.
"Configuration memory
lost"
Hardware
configuration settings
lost.
Contact AMETEK service department
at service@programmablepower.com
to obtain instructions on restoring
configuration data.
Contact AMETEK service department
at service@programmablepower.com
Too many message. Read status
using SYST:ERR query until 0, "No
Error" is received indicating queue
empty.
Unable to complete
query.
Check programming manual for
correct query format and parameters
Query issued but
response not read.
Check application program for correct
flow. Response must be read after
each query to avoid this error.
Check for terminator after query
command.
Query cannot be
completed
Check application program for
multiple queries
Check for terminator after query
command.
" Non-volatile RAM
CONFIG section
checksum failed"
Controller failure
during Self-test.
Contact AMETEK service department
at service@programmablepower.com
" Non-volatile RAM CAL
section checksum failed"
Controller failure
during Self-test.
Contact AMETEK service department
at service@programmablepower.com
" Non-volatile RAM
WAVEFORM section
Controller failure
during Self-test.
Contact AMETEK service department
at service@programmablepower.com