Query Syntax MEASure[:SCALar]:CURRent:AC?
FETCh[:SCALar]:CURRent:AC?
Parameters None
Examples MEAS:CURR:AC? FETC:CURR:AC?
Returned Parameters <NR3>
Related Commands INST:NSEL
MEASure:CURRent:ACDC?
FETCh:CURRent:ACDC?
Phase Selectable
These queries return the ac and dc components of the rms current being sourced at the output
terminals.
Query Syntax MEASure[:SCALar]:CURRent:ACDC?
FETCh[:SCALar]:CURRent:ACDC?
Parameters None
Examples MEAS:CURR:ACDC? FETC:CURR:ACDC?
Returned Parameters <NR3>
Related Commands INST:NSEL
MEASure:CURRent:AMPLitude:MAXimum?
FETCh:CURRent:AMPLitude:MAXimum?
Phase Selectable
These queries return the absolute value of the peak current as sampled over one measurement
acquisition of 4096 data points. Note that the MEAS format returns the non-recurring peak current
(as in a peak hold reading). This value can be cleared with the MEAS:CURR:AMP:RES
command. The FETC format can be used to obtain the recurring or repetitive peak current this
requires the acquisition to be triggered first by either an INIT:ACQ or a MEAS command for
another paramter e.g. current, followed by the FETC:CURR:AMPL:MAX?
Query Syntax MEASure[:SCALar]:CURRent:AMPLitude:MAXimum?
FETCh[:SCALar]:CURRent:AMPLitude:MAXimum?
Parameters None
Examples MEAS:CURR:AMPL:MAX? FETC:CURR:AMPL:MAX?
Returned Parameters <NR3>
Related Commands INST:NSEL
MEASure:CURRent:AMPLitude:RESet
FETCh:CURRent:AMPLitude:RESet
Phase Selectable
These command resets the peak current hold value returned with the MEAS:CURR:AMPL:MAX?
query.
Syntax MEASure[:SCALar]:CURRent:AMPLitude:RESet
FETCh[:SCALar]:CURRent:AMPLitude:RESet
Parameters None
Examples MEAS:CURR:AMPL:RES
Returned Parameters None
Related Commands MEAS:CURR:AMPL:MAX? FETC:CURR:AMPL:MAX?
MEASure:CURRent:CREStfactor?
FETCh:CURRent:CREStfactor?
Phase Selectable