BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 75
OUTPut:RI:MODE
Available on MX/RS/BPS Series II only. This command selects the mode of operation of the
Remote Inhibit protection. The following modes can be selected:
LATChing A TTL low at the RI input latches the output in the protection shutdown
state, which can only be cleared by OUTPut:PROTection:CLEar.
LIVE The output state follows the state of the RI input. A TTL low at the RI input
turns the output off; a TTL high turns the output on.
OFF The instrument ignores the RI input.
The RI output state is saved at power down. The factory default state is LIVE.
Command Syntax OUTPut:RI[:MODE] <mode>
Parameters LATChing | LIVE | OFF
*RST Value LIVE
Examples OUTP:RI:MODE LIVE
Query Syntax OUTPut:RI:MODE?
Returned Parameters <CRD>
Related Commands OUTP:PROT:CLE