AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
40 Manual P/N 7003-961 Rev AA
[:FSCale] Calibrate full-scale AC voltage measurements at
higher temperature
:DC
[:FSCale] Calibrate full-scale AC voltage measurements
:ZERO Cancel AC voltage measurements offset
[:SOURce]
:PHASe Calibrate output phase angle relative to external sync.
:VOLTage
[:AC]
:LRANge
[:FSCale] Calibrate full-scale output voltage at low voltage
range
:ZERO Trim output voltage offset at low voltage range.
:HFRequency Calibrate full scale output voltage at low voltage
range and high frequency.
:HRANge
[:FSCale] Calibrate full-scale output voltage at high voltage
range
:ZERO Trim output voltage offset at high voltage range.
:HFRequency Calibrate full scale output voltage at high voltage
range and high frequency.
:DC
:LRANge
[:FSCale] Calibrate full-scale output dc voltage at low voltage
range.
:ZERO Trim output dc voltage offset at low voltage range.
:HRANge
[:FSCale] Calibrate full-scale output dc voltage at high voltage
range. (positive DC)
:ZERO Trim output dc voltage offset at high voltage range.
:IMPedance
:REAL
[:FSCale] Calibrate the real part of the programmable output
impedance at full-scale value
:ZERO Calibrate the real part of the programmable output
impedance at minimum value
:REACtive
[:FSCale] Calibrate the reactive part of the programmable
output impedance at full-scale value
:ZERO Calibrate the reactive part of the programmable
output impedance at minimum value
:IHARmonic? IEC413 interharmonic