BPS / MX / RS Series SCPI Programming Manual AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA 187
IEC413:IHARmonics:PAUSe
This command will set the pause time in seconds between each interharmonics frequency.
The class must be selected prior to this command. Query with min and max to find the
range of the pause time.
Command Syntax IEC413: IHARmonics:PAUSe <NRf+>
Parameters <seconds>
Examples IEC413:IHAR:PAUS 2
Query Syntax IEC413:IHAR:PAUS?
Returned Parameters <NR1>