Ametek BPS Series Programming Manual Manuale Utente Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 226
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 99
AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
100 Manual P/N 7003-961 Rev AA
4.20 Source Subsystem - PONSetup
This subsystem will control the initial condition of the power source at the power on state.
Subsystem syntax
[SOURce:]
PONSetup:
ALControl 0|1|OFF|ON Set initial ALC state.
CLOCk INT|EXT Set the the clock source to internal or external
CURRent <n> Set the current limit
FREQuency <n> Set the frequency value
NOUTput ONEPhase|THReephase|LAST
Set the command language
OLOad
[:MODE] CVOL|CCUR Set the over load mode const voltage or const
current
OUTPut
[:RELay] 0|1|OFF|ON Set the state of the output relay
PHASe
[:ANGLe] Set the phase angle relative to external
SENSe INT|EXT Set the voltage sense to internal or external
VOLTage
[:LEVel] <n> Set the voltage level
MODE DC|AC|ACDC Set the voltage mode
VRANge 150|300|400 Set the voltage range
WGRoup <n> Set the wave group to 0...3 [3Pi Controller
Only]
PONSetup:ALControl
This command sets the initial ALC mode to either On or Off at power on.
Command Syntax [SOURce:]PONSetup:ALControl <NRf+>
Parameters 0 | 1 | OFF | ON
Examples PONS:ALC 0
Query Syntax PONS:ALC?
Returned Parameters 0 | 1
PONSetup:CLOCk
This command determines the source of its clock at the power on. if internal, the source
uses its internal clock. if external, a clock source must be supplied on the appropriate input.
Command Syntax [SOURce:]PONSetup:CLOCk <source>
Parameters INTernal|EXTernal
Examples PONSetup:CLOCk INT
Query Syntax PONSetup:CLOCk?
Returned Parameters <CRD>
Related Commands FREQ:MODE
Vedere la pagina 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 225 226

Commenti su questo manuale

Nessun commento