DC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 73
T
RIGGER
I
NPUT
R
ESPONSES
The operation surrounding the response due to the receipt of a trigger by a
power module is shown in the next figure. The trigger condition can be based
on establishing either voltage or current settings. Actually, both voltage and
current can be set due to a single trigger receipt.
Figure 3-7. Trigger Input Responses
L
IST
M
ODE
T
RIGGERS
List mode triggering is more complex in that its function is to create complex
operational sequences (Lists) that are timed precisely with respect to an
external trigger or internal event. That is, either trigger or an event can initiate
a sequence. The following figure outlines the logic flow of trigger driven list
processing.