DC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 57
3.6
CALIBRATION SCPI COMMANDS
CAUTION
Before attempting to execute any of the HP/LP DC power supplies calibration commands,
follow the calibration procedures in the ReFlex Power™ Operation Manual (M380056-01),
DC Power Supplies Section. Qualified personnel who are appropriately trained to deal with
attendant hazards must perform calibration. If calibration is not performed properly,
functional problems could arise, requiring that the supply be returned to the factory.
3.6.1 CALIBRATION
SCPI
C
OMMAND
S
UMMARY
CALibrate[n]
:INITial
:CURRent <0+NRf>
[:AMPLitude] <NRf>
[:AMPLitude]?
:PROTection <NRf>
:PROTection?
:VOLTage <0+NRf>
[:AMPLitude] <NRf>
[:AMPLitude]?
:PROTection <NRf>
:PROTection?
:STATe <Bool>
:STATe?
:UNDERVOLTage
:PROTection <NRf>
:PROTection?
:DEFAult
:OUTPut
:CURRent
:COUNTS <NRi>
:FIVEPOINT<1-5> <NRi>
:FIVEPOINT?
:PROTection
:COUNTS <NRi>
:VOLTage
:COUNTS <NRi>
:FIVEPOINT<1-5> <NRi>
:FIVEPOINT?
:PROTection
:COUNTS <NRi>
:MODule
:VOLTage?
:CURRent?