Ametek ReFlex Programming Manual Manuale Utente Pagina 103

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 134
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 102
AC Module Remote Programming ReFlex Power™ Programming Manual
M380056-03 Rev L 99
4.7
MEASURE SCPI COMMANDS
4.7.1 MEASURE
SCPI
C
OMMAND
S
UMMARY
MEASure<n>
:CURRent?
:VOLTage?
:FREQuency?
:PHASe?
:POWer
[:AC]
[:REAL]?
:APParent?
:VAR?
:PFACtor?
:CFACtor?
:IPEak?
4.7.2 MEASURE
SCPI
C
OMMAND
R
EFERENCE
Command
Description
MEASure<n>
MEASURE subset of SCPI command sets. Valid at Module level only.
:CURRent?
Returns measured RMS output current.
:VOLTage?
Returns the RMS output voltage.
:FREQuency?
Returns the set measured frequency of the unit in Hz
:PHASe?
Returns the set
point value of the
phase angle.
:POWer?
Returns real power measurement
:APParent?
Returns apparent power measurement (VA)
:VAR?
Returns reactive power measurement
:PFACtor?
Returns Power Factor measurement
:CFACtor?
Returns current crest factor
:IPEak?
Returns peak current reading
Vedere la pagina 102