Appendix A: Error Messages
Error Conditions (306)
If the monitor displays “SEr320” one of four error conditions relating to the resolver has
occurred. These conditions include primary open, primary shorted, S1, and S4 open or shorted.
To have the monitor display the error condition which has occurred, perform the following
steps:
1. Select the function key.
The monitor displays “F-----”.
2. Select function number 306. Select the enter key.
The monitor will display the exact condition which has occurred. The
following are the possible errors:
P OPEn (Primary Open)
P Shrt (Primary Shorted)
S4OPEn (S4 Open)
S1OPEn (S1 Open)
(F)
306
Chart A-7 LDT-Specic Error
Error Displayed Error Description Solution
SEr331 An error has occurred on the input
device. Fault pulse received from
LDT.
Correct this error by placing the
magnet assembly back into the ac-
tive stroke area, and clear the error.